no multiple diagnostic windows open during
routine operation |
|
?? |
|
start/stop/reset histogram accumulation: control
from dedicated buttons on the JAS window or from a second window dedicated
to JAS control; in normal conditions one should not worry about directories
etc. but just interact with the program from these two windows. |
|
Should be easy to add buttons to JAS menu.
Start/stop/reset is Babar server issue. |
|
synchronization with Run Control to optionally
have histograms accumulated during given periods (runs, fills, ...) |
|
Babar server issue |
|
saving sets of histograms for reference should
allow setting up easily up-to-date multiple references (physics data
taking, backgrounds data taking, cosmics, ...) |
|
Mostly Babar issue. |
|
the comparison of histograms with reference, as
it is now, does not allow to have both histograms simultaneously on the
screen; it should be possible to have them superimposed. |
|
JAS supports overlaying histograms. Must come
from same Job. Histograms in javahist format might be useful. |
|
automatic comparisons with reference should be
implemented wherever possible. |
|
Auto overlay feature would make this easier. |